Circuit Breaker Horizontal Rack PDUs Manufacturers

The Breaker Horizontal Rack PDU in Black is a cutting-edge power distribution unit designed to meet ...

moremore

The 9U Breaker Horizontal Rack PDU in Grey is a powerful and versatile power distribution unit desig...

moremore

The 3U Breaker Horizontal Rack PDU in Grey is a highly efficient and reliable power distribution uni...

moremore
The IDCPDU ND1000 Series Rackmount Power Distribution Units are designed for data centers, wiring closets, and other environments where cost-effective, "always-on" power is required. The rugged, compact design ensures that these products can be used where reliability and density are important.
1. All models feature circuit breaker protection to prevent current overload.
2. Available in DC or AC versions, DC:48V/120V/240V/336V, AC:120V/220V/230V/380V/415V.
3. PDUs with circuit breakers for added safety, with 2-pole and single-pole options.
4. Models with additional surge protection to prevent damage caused by transient surges.
5. LED indicators for power, ground/polarity, and surge protection (if applicable).
6. Hard-wired power input cable.
7. Cold rolled steel construction.
8. Available in 19" rack mount, 1U/3U.
9. Includes mounting hardware and optional adjustable rack mount bracket.
ABOUT US
25YEARS OF
EXPERIENCE
About Us

Coming From China, Marketing To The World.

With the rapid development of cloud computing and mobile internet services, the rapidly increasing density of IT servers and energy consumption have posed many challenges to traditional data centers. As a professional China Circuit Breaker Horizontal Rack PDUs Manufacturers and Circuit Breaker Horizontal Rack PDUs Suppliers, to address the contradiction between customers' constantly changing business needs and low investment and high return, and to meet the future needs of cloud computing, virtualization, blade servers with high density, low consumption, fast deployment, and flexible expansion, effectively improving the work efficiency of data centers, To control investment costs, IDCPDU has launched various power distribution and cabinet solutions for data center infrastructure, achieving energy-saving, fast, and flexible characteristics. The entire series of solutions have four major advantages: "Simpie", "Saving", "Smart", and "Safety". They are currently the environmentally friendly choice for the construction of the new generation of energy-saving modular data centers. At the same time, independently running modular data centers are ideal energy-saving products for future builders, contributing to the future cloud age!

LATEST NEWS

Excellent products with exquisite craftsmanship

Honor

  • 3C
  • CE
  • Environmental Management System Certificate
  • Credit Evaluation Certificate
  • Credit Evaluation Certificate
Rack Series PDUs

Industry Knowledge Expansion

What safety measures are implemented in circuit breaker horizontal rack PDUs to prevent overloads and short circuits?
Circuit breaker horizontal rack PDUs are designed with various safety measures in place to prevent overloads and short circuits. These measures ensure the reliable and safe operation of the PDUs and the connected equipment.

Here are some of the safety features commonly implemented in circuit breaker horizontal rack PDUs:
1. Overload protection: Circuit breaker PDUs are equipped with circuit breakers that provide overload protection. The circuit breakers automatically trip and disconnect the power supply when the current exceeds the maximum rated value. This protects the PDUs and the equipment from damage due to excessive current flow.
2. Short circuit protection: Short circuits can occur when a faulty connection or damaged equipment causes a sudden surge in current. Circuit breaker PDUs are designed to detect short circuits and trip the circuit breaker to interrupt the power flow. This helps prevent damage to the PDUs, connected equipment, and electrical wiring.
3. Current monitoring: Many circuit breaker PDUs feature built-in current monitoring capabilities. Current sensors are installed within the PDU to measure the real-time power consumption of each connected device. This helps to identify potential overloads and allows for proactive load balancing and capacity planning.
4. Intelligent power management: Some circuit breaker PDUs are equipped with intelligent power management features. These PDUs can communicate with a central management system or use network protocols to monitor and control the power flow to individual outlets. Intelligent power management allows for remote monitoring, power scheduling, outlet control, and load shedding to prevent overloads.
5. Thermal overload protection: Higher current flow can lead to increased temperatures within the PDU. To prevent thermal overload and fire hazards, circuit breaker PDUs are often designed with thermal protection mechanisms. These mechanisms monitor the temperature within the PDU and can trip the circuit breaker if the temperature exceeds a safe threshold.
6. Surge protection: Circuit breaker PDUs may also incorporate surge protection devices (SPDs) to guard against voltage spikes and surges. SPDs can redirect excess voltage to the ground and prevent it from damaging the connected equipment. This protection is essential in locations prone to lightning strikes or unstable electrical grids.
7. Mechanical interlocks: In some cases, circuit breaker PDUs include mechanical interlocks that prevent accidental overloads. These interlocks ensure that users cannot insert or remove power cords without first tripping the circuit breaker, reducing the risk of electrical shock or damage to the PDUs or equipment.

How do circuit breaker horizontal rack PDUs handle power factor correction and energy efficiency?
Circuit breaker horizontal rack power distribution units (PDUs) handle power factor correction and energy efficiency in various ways. Power factor correction is the process of improving the power factor of a load to make it closer to unity, which helps reduce the amount of reactive power in the system and improves energy efficiency.

One common method used in circuit breaker horizontal rack PDUs to handle power factor correction is the addition of power factor correction capacitors. These capacitors are connected in parallel to the load and provide the reactive power needed by the load. By providing the necessary reactive power locally, the power factor of the load is improved, and the overall system power factor is increased. This helps in reducing the amount of reactive power drawn from the utility and improves overall energy efficiency.
Another way circuit breaker horizontal rack PDUs handle power factor correction is by utilizing active power factor correction (PFC) technology. Active PFC involves the use of power electronic devices, such as power factor correction controllers, to actively monitor and correct the power factor of the load in real-time. This technology adjusts the waveform of the current drawn by the load to be in phase with the voltage waveform, resulting in a high power factor. Active PFC not only helps improve overall energy efficiency but also enhances the stability and reliability of the power supply.

In terms of energy efficiency, circuit breaker horizontal rack PDUs incorporate various features to optimize energy consumption. One such feature is load balancing. PDUs with load balancing capabilities distribute the power evenly among the different outlets or circuits, ensuring that the load is evenly spread and reducing the risk of overload on specific circuits. By avoiding overloads, energy waste due to excessive heat generated by overloaded circuits is minimized, leading to improved energy efficiency.
Another energy-efficient feature found in circuit breaker horizontal rack PDUs is outlet-level power monitoring. These PDUs come equipped with individual outlet power monitoring capabilities, which allow users to monitor the power consumption of each connected device or server. This information helps identify energy-hungry devices or inefficient equipment, enabling users to take appropriate actions to reduce energy consumption and optimize energy efficiency.

Furthermore, circuit breaker horizontal rack PDUs often incorporate power management software that provides real-time data on power usage and allows users to set power usage thresholds, schedule power cycles, and monitor energy consumption trends. This software-based approach helps efficiently manage power distribution, optimize energy consumption, and identify opportunities for energy savings, ultimately improving energy efficiency.