$cat_detail['cat_name']

Cryptocurrency Mining Industry,
IDC Data centerPower Distribution Solutions

Sustainability & Efficiency Redefined

  • > 95% Recycled Content(TUV Rheinland Certified)
  • < 10% Plastic Content by Weight
  • < 5W ldle Power Consumption
ABOUT US
10YEARS OF
EXPERIENCE
About Us

Coming From China, Marketing To The World.

With the rapid development of cloud computing and mobile internet services, the rapidly increasing density of IT servers and energy consumption have posed many challenges to traditional data centers. As a professional China Server Technology Smart PDUs Manufacturers and Server Technology Smart PDUs Suppliers, to address the contradiction between customers' constantly changing business needs and low investment and high return, and to meet the future needs of cloud computing, virtualization, blade servers with high density, low consumption, fast deployment, and flexible expansion, effectively improving the work efficiency of data centers, To control investment costs, IDCPDU has launched various power distribution and cabinet solutions for data center infrastructure, achieving energy-saving, fast, and flexible characteristics. The entire series of solutions have four major advantages: "Simpie", "Saving", "Smart", and "Safety". They are currently the environmentally friendly choice for the construction of the new generation of energy-saving modular data centers. At the same time, independently running modular data centers are ideal energy-saving products for future builders, contributing to the future cloud age!

Server Technology Smart PDUs Manufacturers

PDU Product Specifications· Output: 36×C13 (lockable) + 6×C39 (lockable), AC 250V· Equipped with 10/...

PDU Product Features· Output: 20 x 20A (SA-20), AC 415V· Provides 10/100M Ethernet interface and one...

PDU Product Features· Output: 24×C19, AC220V· Equipped with 10/100M Ethernet interface and one 485 b...

PDU PRODUCT FEATURES Output AC 380V 32A Provide 10/100m Ethernet one 485 bus The upper limit measure...

PDU  PRODUCT  FEATURES ·Output AC 380/415VAC 24 channels 16A ·Provide RS485 bus ·The upper limit mea...

PDU product features -Output AC 220V 18 way 16A -Provide RS485 bus -Total circuit can be set upper l...

PDU Product Features -Output AC 220V 20 ways 16A -Provide RS485 bus -Total circuit can be set upper ...

PDU Product Features -Output AC 220V 20 ways 16A -Provide RS485 bus -Total circuit can be set upper ...

PDU product features -Output AC 220V 16 way 16A -Provide RS485 bus -Total circuit can be set upper l...

The 20-Outlet C13 C19 Vertical TCP/IP Sensor eco Smart Rack PDU is a highly efficient and intelligen...

Metered PDU 

Metered PDU is designed to provide accurate, real-time visibility of power usage at the rack level, helping operators improve efficiency and prevent overload risks. As part of our Rack series PDU portfolio, this rack power distribution unit is widely used in data center environments where reliable monitoring is essential.

Available in both single-phase and 3 phase rack PDU configurations, our Rack Mount PDU solutions support a wide range of deployment scenarios, from enterprise IT rooms to large-scale facilities. Each Rack PDU is engineered to deliver stable power distribution while offering clear load measurement for better capacity planning.

Compared with traditional basic units, this Metered PDU bridges the gap between standard distribution and advanced Smart PDU or Intelligent PDU functionality, making it an ideal Data Center PDU for professional infrastructure. It is also well-suited as a Server Rack PDU in applications where reliability, accuracy, and operational visibility are critical.

LATEST NEWS

Excellent products with exquisite craftsmanship

Honor

  • UL
  • ROHS
  • ISO-24001
  • ISO-45001
  • ISO 9001
Metered PDU

Industry Knowledge Expansion

What kind of load shedding capabilities can be expected from server technology smart PDUs?
Server technology smart PDUs provide advanced load shedding capabilities that allow data centers to efficiently manage power usage and reduce costs. These capabilities include real-time monitoring, remote management, power cycling, and customizable power profiles.

Real-time monitoring: Smart PDUs provide detailed and accurate real-time data about power usage, including voltage, current, power factor, and energy consumption. This information helps data center operators understand the power demands of different racks, servers, and components. By monitoring power usage in real-time, operators can identify potential overload situations and take proactive measures to prevent downtime and equipment failure.
Remote management: Smart PDUs can be accessed and managed remotely through a web-based interface or specialized software. This allows data center operators to monitor and control power usage from any location. Remote management eliminates the need for physical intervention, reducing the risk of human errors and enhancing operational efficiency. Operators can remotely power on/off individual outlets or groups of outlets, ensuring that power is only supplied to necessary devices, preventing unnecessary power consumption.

Power cycling: Smart PDUs can perform power cycling, which involves remotely shutting down and restarting servers and other critical equipment. This is particularly useful in scenarios where a server becomes unresponsive or experiences performance issues. Power cycling allows operators to remotely reboot servers, eliminating the need for manual intervention. This feature can significantly reduce downtime and improve overall system availability.
Customizable power profiles: Smart PDUs enable data center operators to create customized power profiles for different racks, servers, or groups of servers based on their specific power requirements. These profiles allow operators to define power allocation and prioritize critical servers during peak periods or in the event of power shortages. For example, during periods of high demand, a data center may allocate more power to the servers running mission-critical applications while limiting power to non-essential devices or services.
Load shedding: Load shedding is the process of selectively shedding power or temporarily shutting down non-critical equipment to balance power demand and supply. Smart PDUs are equipped with built-in load shedding capabilities that allow operators to define power priorities and automatically shed non-essential loads during periods of high demand or in the event of a power shortage. Load shedding reduces power consumption, optimizes power usage, and ensures that critical equipment receives sufficient power to operate.

What are the redundancy and failover capabilities of server technology smart PDUs?
Server Technology smart PDUs are designed with several redundancy and failover capabilities to ensure continuous power supply to critical equipment in data centers. These capabilities include advanced monitoring and management features, power redundancy, and failover options.

1. Advanced Monitoring and Management: Server Technology smart PDUs provide real-time monitoring and management features to track power usage, temperature, humidity, and other environmental factors. This allows data center operators to proactively identify potential issues and take necessary actions before they escalate into critical failures.
2. Power Redundancy: Smart PDUs are equipped with multiple power inputs and outputs, enabling power redundancy. They can be connected to separate power sources or power feeds for reliability and fault tolerance. In the event of a power failure or downtime in one power source, the PDU automatically switches to the backup power source, ensuring seamless power supply to critical equipment.
3. Failover Options: Server Technology smart PDUs offer failover options to provide uninterrupted power supply during equipment failures or maintenance activities. Failover functionality can be achieved by configuring power feeds to automatically switch to an alternative PDU port or outlet in the event of an issue. This helps mitigate the risk of downtime and maintain business continuity.
4. Intelligent Load Shedding: Smart PDUs can also perform intelligent load shedding, which is the ability to prioritize power supply to critical equipment during power shortages. In case of a power overload or high demand, the PDU can automatically shed non-essential loads to ensure uninterrupted power supply to essential devices. This feature helps prevent equipment failures and ensures critical operations continue without interruption.
5. Remote Access and Control: Server Technology smart PDUs offer remote access and control capabilities, allowing data center operators to monitor and manage their power infrastructure from anywhere. This remote access facilitates troubleshooting, configuration changes, and firmware updates without physical intervention, reducing the need for onsite visits and saving time during emergencies.
6. Scalability and Modularity: Smart PDUs are designed to be scalable and modular, allowing easy expansion and customization based on changing power requirements. With the ability to add or remove power modules and sensors, data center operators can adapt their power infrastructure as their needs evolve without requiring significant investments or complex rewiring.